Now also catering for SOLAR
INDUSTRY. Approved in terms of ESKOM solar
rebate program.
The one control that does
it all.
With
Intelligent control
Save
Electricity
A Must for all Geysers
Features
Replaces the conventional thermostat with a digital system.
Digital water temperature reading/setting. 4 settings per day.
Control your geyser from the controller.
Convenient to operate.
Microprocessor Intelligent Control.
Quick and steady water temperature control.
Power off memory timer.
Earth leakage protection.
High temperature cut out at 85 degrees centigrade
Element failure detection.
Leaking hot water pipe detection.
Scale build-up detection.
Probe failure detection.
Load shifting capability to off peak periods.
Real-time Clock
Four daily programmable time settings, Monday to Friday , Saturday and
Sundays.
Battery backup on power failure.
Technical
- Replace conventional Thermostat
- Tested by SABS commercial (PTY)LTD in terms of standard IEC 60950
- Average Operating Voltage AC 220V / 50HZ
- Operating Voltage Range AC 160V TO 250V
- Maximum Current 30 AMPERE
- Earth Leakage Protection 25mA, Action time _ 0.1s
- Temperature Display 0 TO 99° C
- Temperature Setting Range 30 TO 65° C
- Maximum Temperature 85° C
- BI-Polar Relay Isolate element in off position
For safety reasons and to avoid any further damage the unit will display an error
code and shut the system down under the following conditions
- Earth Leakage
- Element Failure
- Overheating > 85°C
- Sense Heat Failure e.g. scale build-up, leaking pipes
- Probe Failure
Supports telephone remote control on/off, ability to interface with alarm systems.
- Solar Differential Thermostat. Include All of above plus:
- 2Nd Probe for measuring collector temperature
- Collector temperature display.
- Relay for switching circulation pump.
- Holiday mode temperature control,
- Various protection measures.
|